Wide range of power measuring transducers – including AC volts, AC current, power factor, watts, vars and phase angles measurements. Multi power monitor has output options – Modbus, Ao and Do.
Multi Power Transducers / Monitors
Multi Power Monitor with Modbus
53U
CE RoHS
- 1/4 DIN (96 x 96 mm) panel size
- Four digital displays
- Single type module is usable for all of single-phase/2-wire and 3-wire, three-phase/3-wire and 4-wire systems.
- All measured variables can be transmitted to the host PC via RS-485/Modbus RTU.
- Energy count pulse or limit alarm output selectable
- Up to 4 optional analog outputs
- Programming lock to prevent unwanted configuration changes
- Input range up to 480 Vac, 1 A or 5 A
|
Multi Power Monitor with Modbus & CC-Link
54U / 54UC / 54UL
RoHS
- 110 x 110 mm panel size
- Robust screw terminal connection
- Four digital displays
- 60-segment bargraph
- Single-phase/2-wire and 3-wire, three-phase/3-wire and 4-wire systems
- All measured variables can be transmitted to the host PC via RS-485/Modbus RTU or CC-Link,LONWORKS
- Energy count pulse or limit alarm output selectable
- Up to 4 optional analog outputs
- Programming lock to prevent unwanted configuration changes
- Input range up to 480 Vac, 1 A or 5 A
| Modbus:54U |
CC-Link:54UC |
LONWORKS:54UL |
 |
 |
 |
|
Multi Power Transducer with Modbus
L53U
CE RoHS
- Single type module is usable for all of single-phase/2-wire and 3-wire, three-phase/3-wire and 4-wire systems.
- All measured variables can be transmitted to the host PC via RS-485/Modbus RTU.
- Energy count pulse or limit alarm output selectable
- Up to 4 optional analog outputs
- Remote and local programming using the PC Configurator Software
- Input range up to 480 Vac, 1 A or 5 A
- DIN rail mounted
|
Multi Power Transducer with 10 Analog Outputs
LSMT4
RoHS
- Measures AC current, voltage, active/reactive/apparent power and power factor
- 10 x DC voltage/mA outputs plus 2 x Do
- Parameters are freely programmable with the front control buttons or by PC
- DIN rail mounted
|
Power Transducers
Power Transducers
LT Series
CE RoHS
- AC current up to 5A,
AC voltage up to 550V.
- True RMS sensing
- Auxiliary powered and self powered types selectable
- Surface or DIN rail mounting
- M4 screw terminal
- Conform to IEC 60688
- Optional terminal cover
- Additional pulse rate output for totalizing counter for watt transducers
|
High AC Current Transmitter with lntegral Probe
CTS2
- Detecting high current at the flexible current probe and
providing a porportional low-ripple standard signal
- appropriate for computer use
- Wide frequency band can be accepted
- Clipped around a conductor without disconnecting the conductor
- Rogowski coil type
- Isolation up to 2000 V AC
- High-density mounting
|
Clamp-on Current Sensors
Clamp-on Current Sensors
CLSC
RoHS
- Easy-to-install, clamp-on type current sensor
- Over-voltage clamp element for safety in open circuit
- 1A Output
- Wide frequency band
- Screw terminal connection
| Model CLSC |
-10 |
-25 |
-50 |
-60 |
| Applicable max. wire diameter |
24 mm |
24 mm |
36 mm |
36 mm |
| Primary rating |
100A |
250A |
500A |
600A |
| Secondary rating |
1A |
1A |
1A |
1A |
|
Clamp-on Current Sensors
CLSD
RoHS
- Easy-to-install, clamp-on type current sensor
- Over-voltage clamp element for safety in open circuit
- 1A Output
| Model CLSD |
-A |
-B |
-C |
-D |
| Applicable max. wire diameter |
24 mm |
36 mm |
60 mm |
100 mm |
| Primary rating |
200A |
400A |
1000A |
2000A |
| Secondary rating |
1A |
1A |
1A |
1A |
|
Clamp-on Current Sensors
CLSE
CE RoHS
- Easy-to-install, spring-loaded, clamp-on type current sensor
- Over-voltage clamp element for safety in open circuit
- Wide frequency band
- Screw terminal connection
| Model CLSE |
-R5 |
-05 |
-10 |
-20 |
-40 |
-60 |
| Applicable max. wire diameter |
10mm |
10mm |
16mm |
24mm |
36mm |
36mm |
| Primary rating |
5A |
50A |
100A |
200A |
400A |
600A |
| Secondary rating |
1.65mA |
20mA |
20mA |
20mA |
20mA |
20mA |
|
|