Application Notes
Power Measurement

The old company name and logo may still be indicated on products, printed materials or web site published before its change. Those shall be read as the new ones.

Isolation / Temperature / Pulse / Strain Gauge / Potentiometer / AC
Pneumatic / Function / Power Supply / Alarm / Power Mesurement
Trend & Log/Communication / Surge Protection / Other Topics

Application
  • Multi Power Monitor 53U Series
– Automotive Supplier Able to Detail Energy Usage –

030027 What is an effective or a root mean square value of an alternating current and of an alternating voltage?
[ HTML ] [ MS Word MS Word 60k ]
030028 What is average power of an AC circuit?
[ HTML ] [ MS Word MS Word 72k ]
030029 What is the electric power in an electric circuit with a pure resistance?
[ HTML ] [ MS Word MS Word 152k ]
030030 How can the electric power of an electric circuit with resistance and inductance be calculated?
[ HTML ] [ MS Word MS Word 88k ]
030031 Why is a three-phase alternating current used often for electric devices?
[ HTML ] [ MS Word MS Word 104k ]
030032 What is bi-directional power flow?
[ HTML ] [ MS Word MS Word 144k ]
030033 Why does phase difference occur? What is power factor?
[ HTML ] [ MS Word MS Word 100k ]
030034 Why does waveform get distorted?
[ HTML ] [ MS Word MS Word 112k ]
030035 What does the CT protector (M-System model CTM) that is installed onto the socket of the transmitter do?
[ HTML ] [ MS Word MS Word 96k ]
030036 The display of the current meter on our control panel differs from that of a digital indicating tester. The current meter receives the signal from a CT transmitter. Why does the difference occur?
[ HTML ] [ MS Word MS Word 80k ]
030037 What is the two-wattmeter method that is suitable to unbalanced load in measurement of three-phase power?
[ HTML ] [ MS Word MS Word 96k ]
030038 Can we obtain integrated power with a power transducer?
[ HTML ] [ MS Word MS Word 104k ]
032020 We want to measure active power in 3-phase/3-wire, balanced system, with single current transformer, not two.
[ HTML ] [ MS Word MS Word 108k ]
032021 Combination of DCS with power management system
[ HTML ] [ MS Word MS Word 80k ]
032022 What are the input waveform requirements when using average sensing VS. RMS sensing type current/voltage transducers?
[ HTML ] [ MS Word MS Word 72k ]
032023 M-System's Power Transducers have no earth ground connection terminal. Why is this?
[ HTML ] [ MS Word MS Word 112k ]
032024 I want to measure electric power with a power transducer to provide a pulse output&. Do you have a transducer which can correspond to the change of CT or PT after installed and wired, and the pulse unit (Wh/pulse) of which can be set on site?
[ HTML ] [ MS Word MS Word 112k ]
032025 We are planning to monitor AC current signal 0-5A from a current transformer (CT) on a PC. Because the scanning time of PC is fast, we are looking for a fast-response type Power Transducer to meet the feature of this measurement target.
[ HTML ] [ MS Word MS Word 108k ]
032026 Bidirectional current transducer -- What is this transducer used for? How different from normal AC current (CT) transducers such as model LCE?
[ HTML ] [ MS Word MS Word 92k ]
032027 How to get two pulse outputs for bidirenctional power?
[ HTML ] [ MS Word MS Word 112k ]
032036 Why do we need to mount a CT protector on plug-in CT transducers?
[ HTML ] [ MS Word MS Word 80k ]
032069 How to determine the VT input value for 3-phase/4-wire configuration for M-System's watt transducers such as the model LTWT?
[ HTML ] [ MS Word MS Word 216k ]
032075 We have just integrated two equipment systems together. Now besides the instantaneous power consumption of each system, we also need to monitor the aggregated power consumption as well. Do you have any good advice for this?
[ HTML ] [ MS Word MS Word 156k ]
032094

In order to monitor an electric power system in the factory, we monitor the load current of each motor equipped in each assembling line. We[]d like to convert the motor load current into 1-5 Vdc standard signals and put it to existing data monitoring instrument.
However, there is a strict budget limit then we like to achieve this system with low price as much as possible. Does M-System have any solution?
[ HTML ] [ MS Word MS Word 171k ]

032104

We plan to install a simple measuring instrument in order to measure motors’ load current in each manufacturing line at factory. Specifically, we consider installing them as combination use of an AC current transducer and an indicator.
We can not attach a CT (Current Transformer) at every load current check-up. We are looking for an AC current transducer responding to clamp-on current sensor so that we can measure each motor load current without needing a CT.
[ HTML ] [ MS Word MS Word 206k ]

032128

Our factory has a private electric generator and we do power selling as well as power buying. From a viewpoint of power management, we’d like to measure each item of Line current (A), Line voltage (V), Watt (W), Var (var) and Power factor (PF).
As for W, var and PF, we are looking for the transducer, which enables to distinguish power buying from power selling with 4-20mA output proportionally. Does M-System have any suitable power transducer?
[ HTML ] [ MS Word MS Word 236k ]

032129

We are monitoring the power of a production line. Although the instantaneous power is already monitoring at the central monitor room, additionally we like to display rough value of current at site. Specifically, we want to classify the current values into three to four levels in advance and display the present current value with the corresponding lamp lit. We need to install measuring equipment easily without interrupting the facilities, and furthermore, we do not want to have the generated in-rush current at the time of starting the facilities indicated by the lamps. Is there any method to realize these requirements? The normal AC current is around 45 A and the maximum current is around 50 A.
[ HTML ] [ MS Word MS Word 152k ]

032135

We’d like to measure secondary load current of an Inverter. In order to avoid stopping the factory line in service, we’d like to use clamp-on type current sensor to measure the current. We have several different types of inverters and their measurement current is each different. Let’s say some inverters’ current range are 0-150A and the others’ are 0-300A or other range. Does M-System have any suitable CT transmitters for this kind application?
[ HTML ] [ MS Word MS Word 136k ]

032138

We are monitoring plant facility’s value of power, current, voltage and etc. by existing old indicators. They are very old, so we are planning to replace the indicators to new one. We are looking for a new one, which can measure and display several variables of measured data by itself. We also want to collect measured data by PC. Does M-System have any suitable indicator?
By the way, we hope the new indicators to fit the existing panel cutout DIN size 96 x 96mm.
[ HTML ] [ MS Word MS Word 251k ]