Signal Conditioners

Strong emphasis on quality assurance system

Kyoto Techno Center has the Reliability Testing Section of the Quality Assurance Dept. to conduct a type test of all products released from
M-System. We conduct a type test to verify the quality on not only new products but also products of which we changed the design.

Evaluation test

Our Quality Assurance Dept. conducts a prototype evaluation before releasing a new product. We validate the products based on the various regulations / standards and the company standards mainly classified into four categories. In addition, we conduct an EMC (*5) test as a part of the evaluation test.
Our anechoic chamber used for the EMC test is certified and registered by the official body (VCCI (*6) ), and we conduct an official test instead of a simplified test.

Company standards Number of standards
Standards on the functions 29
Standards on the performance 31
Standards on the reliability 45
Standards on the mechanism 9
Total 114
Anechoic chamber certified and registered by the official body (VCCI*2)

Anechoic chamber certified and registered by the official body
(VCCI (*6) )

A large shielded room of 6 m x 6 m where multiple tests can be conducted simultaneously

A large shielded room of 6 m x 6 m where multiple tests can be conducted simultaneously

The EMC test required for M-System to acquire the CE marking has the following test items and all of them are conducted by our own facility at Kyoto Techno Center (Kizugawa-City, Kyoto).

EMC test required by the EMC directive
Reference standards Base standards Name Test locations in
M-System
EN61000-6-2 EN61000-4-2 Electrostatic discharge immunity test Shielded room
EN61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test Anechoic chamber
EN61000-4-4 Electrical fast transient/ burst immunity test Shielded room
EN61000-4-5 Surge immunity test Shielded room
EN61000-4-6 Immunity against conducted emission
induced by radio-frequency fields
Shielded room
EN61000-4-8 Power frequency magnetic field immunity test Shielded room
EN61000-4-11 Voltage dips, short interruptions and
voltage variations immunity tests
Shielded room
EN61000-6-4 CISPR16-1-1
CISPR16-1-4
CISPR16-2-3
Radiation emissions Anechoic chamber
CISPR16-1-1
CISPR16-1-2
CISPR16-2-1
Conduction emissions Shielded room
CISPR22 Electrical communications/circuit network port Shielded room

(*5) EMC (Electro Magnetic Compatibility): Tests to check the effect by applying an electromagnetic noise to a device and to measure the electromagnetic wave and conductive common mode noise emitted from the device.

(*6) VCCI (Voluntary Control Council for Interference by information technology equipment): Formerly known as Voluntary Control Council for Information Technology Equipment. An industry organization in Japan that discusses the regulations on the radio waves emitted from the information technology equipment