Pulse to Analog

  • Fixed range, low cost
    Open collector, mechanical contact, 5V/12V/24V pulse. Specific input range up to 100 kHz
    100-240 V AC or 24 V DC powered (CE for 24 V DC type)
    M5PA
    M5PA CEUKCA
  • Fixed range signal splitter, low cost
    Open collector, mechanical contact, 5V/12V/24V pulse. Specific input range up to 100 kHz
    Independent output ranges selectable
    100-240 V AC or 24 V DC powered (CE for 24 V DC type)
    W5PA
    W5PA CE
  • PC & "One-Step Cal" programmable I/O
    Open collector, dry contact, voltage pulse, two-wire current, RS-422 line driver selectable; 0-200 kHz max.
    Excitation 4 V, 8 V or 12 V selectable
    Output selectable within 0-20 mA and ±10 V
    100-240 V AC or 24 V DC powered
    DIP switch or PC configuration
    101-point linearization using the PC Configurator
    M3LPA2
    M3LPA2 CEULcUL
  • PC programmable I/O
    Open collector, mechanical contact, voltage pulse, two-wire current, RS-422 line driver selectable; 0-200 kHz max.
    Excitation 4 V, 8 V or 12 V selectable
    Output selectable within 0-20 mA and ±10 V
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    M2XPA3
    M2XPA3 CEULcULUKCA
  • Fixed range
    Dry contact or voltage pulse. Specific input range up to 10 kHz
    Excitation 12 V @30 mA
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    M2SP
    M2SP CEULcULUKCA
  • Fixed range signal splitter
    Dry contact or voltage pulse. Specific input range up to 10 kHz
    Excitation 12 V @30 mA
    Independent current/voltage output ranges can be specified.
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    W2SP
    W2SP CEULcUL
  • Fixed range, ultra-slim
    Open collector, mechanical contact, 5V/24V pulse. Specific input range up to 100 kHz
    24 V DC powered
    M6
    M6SPA Tension-Clamp Type CEULcUL
    M6NPA Screw Terminal Type CEULcUL
    M6DPA Euro Terminal Type CEULcUL

Analog to Pulse

  • Fixed range frequency output
    Specific input range up to 300 V
    Open collector, 5V pulse or mercury relay output. Specific output range up to 1 kHz.
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    M2AP
    M2AP CEULcUL
  • Fixed range frequency output signal splitter
    Specific input range up to 300 V
    Open collector, 5V pulse or mercury relay output. Specific output range up to 10 kHz.
    100-240 V AC or 24 V DC powered.
    UL/cUL Class I, Div. 2 approval
    W2AP
    W2AP CEULcUL

Pulse Isolation, Scaling

  • Pulse isolator
    Mechanical contact, open collector or voltage pulse input; 0-10 kHz max.
    Open collector, voltage pulse or mercury relay output
    100-240 V AC or 24 V DC powered
    UL Class I, Div. 2 approval
    M2PP
    M2PP CEULUKCA
  • Pulse scaler
    Open collector, mechanical contact, 5V pulse or two-wire current pulse input; 0-100 kHz max.
    Excitation 12 V/24 V @30mA
    Open collector, voltage pulse, AC/DC switch output
    Scaling factor adjustable of 1.000 x 1/1 to 0.0001 x 1/1000000
    100-240 V AC or 24 V DC powered
    UL/cUL Class I, Div. 2 approval
    M2PRU
    M2PRU CEULcUL
  • Pulse isolator, signal splitter
    Mechanical contact, open collector or voltage pulse input; 0-10 kHz max.
    Open collector, voltage pulse or Dry contact AC/DC switch output
    100-240 V AC or 24 V DC powered
    W2PP
    W2PP CEUKCA
  • Pulse isolator, ultra-slim
    Mechanical contact, open collector, voltage pulse or two-wire current input; 0-100 kHz max.
    Open collector or voltage pulse output
    24 V DC powered
    M6
    M6SPP Tension-Clamp Type CE
    M6NPP Screw Terminal Type CE
    M6DPP Euro Terminal Type CE
  • Pulse isolator, selectable excitation
    Dry contact, voltage pulse or two-wire current input; 0-100 kHz max.
    Excitation 5 V or 12 V
    Open collector, voltage pulse or relay contact output
    100, 110, 115, 120, 200, 220, 240 V AC or 12, 24, 48 V DC powered
    YPD
  • Pulse isolator, signal splitter, selectable excitation
    Dry contact, voltage pulse or two-wire current input; 0-100 kHz max.
    Excitation 5 V or 12 V
    Open collector, voltage pulse or relay contact output (two)
    100, 110, 115, 120, 200, 220, 240 V AC or 12, 24, 48 V DC powered
    WYPD
    WYPD

Encoder Input

  • PC programmable I/O, encoder input
    Converts a two-phase forward and reverse rotation pulse signal with 90 degree phase difference into a forward and reverse speed signal.
    Open collector, voltage pulse, RS-422 line driver selectable; 0-100 kHz max.
    Excitation 5 V or 12 V selectable
    Output selectable within 0-20 mA and ±10 V
    100-240 V AC or 24 V DC powered
    M2XRP2
    M2XRP2 CEULcUL
  • Rotary encoder speed input
    Converts a two-phase forward and reverse rotation pulse signal with 90 degree phase difference into a forward and reverse speed signal.
    Open collector, voltage pulse or RS-422 line driver pulse inputs
    Excitation 5 V, 12 V or 24 V
    85-132 V AC or 12, 24, 48, 110 V DC powered
    JRP2
    JRP2

    Applications: Measuring moving speed of a machine with a rotary encoder

  • Rotary encoder position input
    Converts a two-phase forward and reverse rotation pulse signal with 90 degree phase difference into a forward and reverse position signal.
    Open collector, voltage pulse or RS-422 line driver pulse inputs
    Excitation 5 V, 12 V or 24 V
    85-132 V AC or 12, 24, 48, 110 V DC powered
    JRQ2
    JRQ2

    Applications: Measuring moving distance of a machine with a rotary encoder

  • Rotary encoder pulse isolator
    Galvanically isolates two pulse rate signals from a rotary encoder.
    Dry contact, voltage pulse, two-wire current pulse, or RS-422 line driver pulse inputs.
    Relay, open collector or voltage pulse outputs
    Excitation 5 V, 12 V or 24 V
    85-132 V AC or 12, 24, 48, 110 V DC powered
    RPPD
    RPPD CE

    Applications: Isolating field pulse signals in order to reduce noise interference