ec_z750_a_a
5/48

5SignalConditionersIndicatorsPowerTransducersRecordersTemperatureControllers4-wire Signal Conditioners2-wireSignal ConditionersFunction Modules & Retrofit ProductsLimit AlarmsTower LightsMultiplex Transmission SystemPID ControlComponentsRemote I/OWeb Data LoggersElectric ActuatorsLightning SurgeProtectorsSignal Conditioners Selection Guide 1Focused New Products for JapanSignal Conditioners Selection Guide 2M-SystemCompanyW2 Series Signal SplitterPLC networkIsolationOutput 1 DriverOutput 2 DriverAiCPU moduleNetwork modulePower supply moduleRecorderPLCOpen-circuitGround LoopShort-circuit4-wire Signal ConditionersM2/W2 SeriesCompact Plug-in Socket Mounted Signal Conditioners ❙Wide selection of input/output ranges and functions ❙W2 Series provide a second isolated output of independent range ❙DIN rail or surface mounting ❙2000 Vac isolation ❙Base socket included with the modulesM2E SeriesCompact Signal Conditioners with OEL Display ❙Bright, high-contrast OEL (Organic Electroluminescent) display ❙Programming parameters and selections are shown in text scrolling on the display: intuitive, easy programming just like operating a cell phone ❙Field selectable I/O range ❙PC configuration is also availableM5/W5 SeriesTerminal Block Type Compact Signal Conditioners ❙Only 41 mm (1.61 in) deep, terminal block style modules can be installed anywhere, even behind the panel cover. ❙W5 Series provide a second isolated output of independent range ❙DIN rail mounting ❙2000 Vac isolationWhy Isolate the Second Output?W2 SeriesSignal SplittersM2 SeriesChannel-to-channel Isolation Enhances the Overall System ReliabilityWhenever you want to add another device such as a recorder to a sensor signal loop connected to PLC’s analog input module, a signal splitter that can output two isolated signals is recommended.The loop’s load capacity may allow to connect one more load in series to (4-20 mA current signal) or in parallel to (1-5 V voltage signal) an existing receiving instrument. However, in such a configuration, short-circuit, open-circuit or ground loop at one part of the loop could affect the entire system.Galvanically separating each part of the loop is beneficial to contain any damage to the limited section in case of an accident, thus to making troubleshooting easier, minimizing the system downtime. W5 SeriesSignal SplittersM5 SeriesM2E SeriesNEWLong texts scrolling on the displaySetting View

元のページ 

10秒後に元のページに移動します

page 5

※このページを正しく表示するにはFlashPlayer10.2以上が必要です