Non-isolated Current Loop Supplies

  • Low profile, low cost
    4-20 mA input
    Supply output 24-28 V @22 mA
    Signal output 4-20 mA and 1-5 V
    24 V DC powered
    M5D
    M5D CEUKCA
  • Plug-in socket mounted, 30 mA
    4-20 mA input
    Supply output 24 V @30 mA
    Signal output 4-20 mA and 1-5 V
    100-240 V AC or 24 V DC powered
    M2D2
    M2D2 CEULcUL

Isolated Current Loop Supplies

  • Low profile, low cost
    4-20 mA input
    Supply output 24-28 V @22 mA
    Signal output 4-20 mA and other voltage or current range
    100-240 V AC or 24 V DC powered (CE for 24 V DC type)
    Economical model
    M5DY
    M5DY CEUKCA
  • Low profile, low cost, signal splitter
    4-20 mA input
    Supply output 24-28 V @22 mA
    Signal output 4-20 mA and other voltage or current range
    Independent output ranges selectable
    100-240 V AC or 24 V DC powered (CE for 24 V DC type)
    W5DY
    W5DY CE
  • Plug-in socket mounted
    4-20 mA input
    Supply output 24-28 V @22 mA
    Signal output 4-20 mA and other voltage or current range
    100-240 V AC or 24 V DC powered
    M2DYS
    M2DYS CEULcUL
  • Plug-in socket mounted, signal splitter
    4-20 mA input
    Supply output 24-28 V @22 mA
    Independent current/voltage output ranges can be specified
    100-240 V AC or 24 V DC powered
    W2DYS
    W2DYS CEULcULUKCA
  • Thin profile type, AC powered
    4-20 mA input
    Supply output 24-28 V @22 mA
    Signal output 4-20 mA and other voltage or current range
    100-240 V AC or 24 V DC powered
    M3DY
    M3DY CE
  • Thin profile type, DC powered
    4-20 mA input
    Supply output 24-28 V @22 mA
    Signal output 4-20 mA and other voltage or current range
    24 V DC powered
    M3SDY
    M3SDY CE
  • Ultra-slim
    4-20 mA input
    Supply output 24-30 V @22 mA
    Signal output 4-20 mA, 0-10 V, 0-5 V, 1-5 V
    24 V DC powered
    M6
    M6SDY Tension-Clamp Type CEULcUL
    M6NDY Screw Terminal Type CEULcUL
    M6DDY Euro Terminal Type CEULcUL

HART Transparent Isolators

  • Plug-in socket mounted
    4-20 mA input
    Supply output 24-28 V @22 mA
    Signal output 4-20 mA
    100-240 V AC or 24 V DC powered
    M2DYH2
    M2DYH2 CE
  • Plug-in socket mounted, current repeater, HART transparent
    Isolation between 2-wire transmitters and current loop supplies
    4-20 mA input
    Supply output 24-28 V @22 mA
    signal output 4-20 mA
    100-240 V AC or 24 V DC powered
    M2DYHR
    M2DYHR CE
  • Plug-in socket mounted, HART transparent signal splitter
    4-20 mA input
    Supply output 24-28 V @22 mA
    Independent current output ranges can be specified
    100-240 V AC or 24 V DC powered
    W2DYH2
    W2DYH2 CEUKCA
  • Plug-in socket mounted, galvanic isolator
    4-20 mA input
    Supply output 22 V @22 mA
    Signal output 4-20 mA
    24 V DC powered
    ATEX / FM intrinsically safe associated apparatus
    A3DYH
    A3DYH CEATEXFM

Linearization

  • Square root extraction
    4-20 mA input
    Supply output 24-28 V @22 mA
    Signal output 4-20 mA and other voltage or current range
    100-240 V AC or 24 V DC powered
    Low-end cutout
    M2DNY
    M2DNY CEULcUL
  • Square root extraction, signal splitter
    4-20 mA input
    Supply output 24-28 V @22 mA
    Independent current/voltage output ranges can be specified
    100-240 V AC or 24 V DC powered
    Low-end cutout
    W2DNY
    W2DNY CEULcUL
  • PC & "One-Step Cal" programmable
    4-20 mA input
    Supply output 24-28 V @22 mA
    Output selectable within 0-20 mA and ±10 V
    24 V DC powered
    DIP switch or PC configuration
    101-point linearization using the PC Configurator
    M3LDY
    M3LDY CEULcUL

DC Power Supplies

  • DC power supply, 24 V DC, 2.5 A/60 W
    100-240 V AC input
    Supply output 24 V -10/+15%
    Max. load current 2.5 A
    Maintenance forecast monitor function
    MDC5
    MDC5 CEULcULVDE
  • DC power supply, 24 V DC, 5 A/120 W
    100-240 V AC input
    Supply output 24 V -10/+15%
    Max. load current 5 A
    Maintenance forecast monitor function
    MDC6
    MDC6 CEULcULVDE
  • DC power supply, 24 V DC, 10 A/240 W
    100-240 V AC input
    Supply output 24 V -10/+15%
    Max. load current 10 A
    Maintenance forecast monitor function
    MDC7